Standards

Fire

BS 476:1987 Fire tests on building materials and structures

  • Part 20 Method for determination of the fire resistance of elements of construction (general principles)
  • Part 22 Method of determination of the fire resistance of non-load bearing elements of construction
  • Part 23 Method for the determination of the contribution of components to the fire resistance of a structure.

BS EN 1364 – 1:1999 Fire tests on building materials and structures

BS EN 1365 – 2:2000 Fire resistance tests for load bearing elements Part 2 Floors & Ceilings

Acoustics

BS EN ISO 10140-2:2010 Acoustics – laboratory measurement of should insulation of building elements

BS EN ISO 717 Acoustics – rating of sound insulation in buildings and of building elements

  • Part 1 Airborne Sound Insulation
  • Part 2 Impact Sound Insulation

Mechanical

BS 5234 – 2:1992 Partitions (including matching linings)

  • Part 1 Code of practice for design and installation
  • Part 2 Specification for performance requirements for strength and robustness including methods of test

General

BS EN 14195:2005 Metal framing components for gypsum plasterboard systems – Definitions, requirements and test methods

BS EN 10143:1993 Specification for continuously hot-dip metal coated steel

BS EN 10162:2003 Specification for cold rolled steel sections

BS 8212:1995 British Standard code of practice for dry lining and partitioning using gypsum plasterboard

BS 4787:1995

  • Part 1 Internal and external wood door sets, door leaves and frames

Suspended Ceilings

BS 8290:1991

  • Part 1 Code of practice for design
  • Part 2 Specification for performance requirements of components and assemblies and methods of test
  • Part 3 Code if practice for installation and maintenance

BS EN 13964 Suspended Ceilings – Requirements and Test Methods

BS 8000-8:1994 Workmanship on building sites

BS EN 520:2004 Gypsum plasterboards – Definitions requirements and test methods

BS 7364:1990 Galvanised steel studs and channels for stud and sheet partitions and linings using screw fixed gypsum wallboards

BS EN 10327:2004 Continuously hot-dip coated strip and sheet of low carbon steel for cold forming

BS EN 10162:2003 Specification for cold rolled steel sections

Testing Facilities

The Speedline range of dry lining and ceiling systems have been independently tested or assessed by accredited laboratories.

This website comprises of a collation of data carried out using a number of different testing facilities.

Facilities used:

  • BRE Garston – Fire, Acoustic & Mechanical
  • BTC East Leake – Fire & Acoustic
  • Salford University – Acoustic & Mechanical
  • Strathclyde University – Mechanical
  • WFRC Warrington – Fire
  • Aycliffe Research – Fire
  • SRL Sudbury – Acoustic
  • BM TRADA – Fire

Please contact [email protected] for further information on the individual test or to see where the test or assessment was carried out quoting the system reference.

All test data and system specifications are for systems constructed with materials and components as shown.  The inclusion of other components without prior approval or constructed on site contrary to this website will invalidate test certification and system performance.

Information Hub All Resources

SIG is pleased to announce their Speedline Partition Systems have passed the assessment against the Code for Construction Product Information (CCPI). *The assessment covers all non-load bearing metal stud partition systems, including shaft wall, with 30-, 60-, 90-, and 120-minute fire resistance.

CCPI

Speedline is totally committed to the concept and future success of supporting BIM (Building Information Modelling).

BIM

The Speedline Drywall Systems manual is a guide to offer you the best dry lining solution for your project utilising the extensive, independently tested range of Speedline Drywall Systems.

Drywall Manual

The manufacturer of the Speedline metal systems has been recognised by the award of BS ISO 14001:2004 for it’s Environmental Management System and the Steel Construction Sustainability Charter and were the first cold roll-forming company to be awarded the prestigious Gold standard.

Sustainability

Speedline metal systems are manufactured in accordance with Occupational Health and Safety management System BS OHSAS 18001:2007

Health & Safety

From the initial concept of your project, we can provide full technical support, including specification advice and provide NBS clauses and specific design details.

Technical Support

Each combination of Speedline metal, plasterboard and insulation has a unique system reference number.  This unique reference number allows you to download all relevant information.

Data Sheets

Correct installation and specification of Speedline Drywall Systems and components is the responsibility of the contractor and design team.  Construction should be in accordance to all relevant regulatory requirements and appropriate UK construction guidance and guidelines.

Standards

Speedline Systems Assurance is a dedicated warranty covering a comprehensive range of drywall solutions, offering peace of mind for clients, specifiers and contractors.

Systems Assurance